Tuesday, March 26, 2013

NIC Teaming and Cisco Switch Configuration



Server Configuration
       Server Access port configuration 
Server access ports typically fall into three categories:
  1. Normal servers which require simple gigabit connectivity with fail on fault cards (what HP calls Network Fault Tolerance – NFT)
  2. High bandwidth servers which require two gigabit throughput using aggregation
  3. VMWare servers which require special configuration 
Some initial thoughts
       Nowadays auto-negotiation of speed and duplex works well with server gigabit interfaces so do not try and set the speed or duplex manually. One reason is auto-negotiation enables the cable-tester built into some gigabit Ethernet modules to function.

For example:
switch#test cable-diagnostics tdr interface gi1/2/1
TDR test started on interface Gi1/2/1
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
switch#show cable-diagnostics tdr interface gi1/2/1
TDR test last run on: August 06 13:58:00
Interface Speed     Pair Cable length Distance to fault   Channel Pair status
             --------- ----- ---- ------------------- ------------------- ------- ------------
Gi1/2/1   1000  1-2  0    +/- 6  m       N/A                Pair B  Terminated 
                       3-6  0    +/- 6  m       N/A                 Pair A  Terminated 
                       4-5  0    +/- 6  m       N/A                 Pair D  Terminated 
                       7-8  0    +/- 6  m       N/A                 Pair C  Terminated  


       If a server comes in at 100 Mbps and the server is also set to auto/auto, it is likely that there is a cable fault (gigabit requires all pairs to be terminated where 100 Base-T does not).
       Access ports should also be set to spanning-tree portfast as per established practice.
       Port-security is also worth mentioning as it is NOT compatible with dual-homed servers using HP’s network teaming software. Any cable fault on NIC 1 results in the MAC address shifting over to NIC 2’s port and the switch sees this as a security violation, blocks traffic and generates this syslog message.

Normal ServersSwitch Configuration

interface <interface name>
 switchport
 !Set an access VLAN
 switchport access vlan <###>
 !Force access mode
 switchport mode access
 !Set an acceptable broadcast storm level
 storm-control broadcast level 0.10
 !Port-security is not compatible with dual-homed servers 
 no switchport port-security
 no switchport port-security maximum
 no switchport port-security violation restrict
 spanning-tree portfast
end

Server configuration
       The default configuration on HP servers for a teaming interface is Type: Automatic and Transmit: Automatic. This configuration will, on non-etherchannel switch ports, default to Transmit Load Balancing with Fault Tolerance (TLB). One NIC will transmit and receive traffic whilst the other will only transmit.
       From a network point of view this makes troubleshooting difficult, as transmit traffic is spread over two NICs with two MAC addresses and receive traffic is directed to just one NIC depending on what NIC responds to ARP requests. 
Our PREFERRED configuration is to use either: 
NFT Teaming Configuration
NFT Teaming with preference configuration
       Two servers that are known to exchange a lot of traffic with each other but do not use Etherchannel should use NFT with preference and ensure that the active NICs on both servers go to the same switch.

High Bandwidth Servers

Switch Configuration

Note: most settings MUST match between all ports in the same Etherchannel group (e.g. storm-control; access mode; and vlan).
interface <interface name> switchport
 !Set an access VLAN switchport access vlan <###>
 !Force access mode switchport mode access
 !Set an acceptable broadcast storm level storm-control broadcast level 0.10
 !port-security is not compatible with channelling  no switchport port-security
 no switchport port-security maximum
 no switchport port-security violation restrict
 !Force LACP & enable as passive mode channel-protocol lacp
 channel-group <#> mode passive
 spanning-tree portfast
 !Force flowcontrol off to stop any channelling issues
 !Intel cards default to no flow control; HP on-board default to on

 flowcontrol receive off
 flowcontrol send off
end


Sample output showing two links being aggregated:
switch#show int po100 etherchannel
Port-channel100   (Primary aggregator)

Age of the Port-channel   = 1d:01h:38m:34s
Logical slot/port   = 14/4          Number of ports = 2
HotStandBy port = null
Port state          = Port-channel Ag-Inuse
Protocol            =   LACP
Fast-switchover     = disabled

Ports in the Port-channel:

Index Load Port    EC state    No of bits
------+------+------+------------------+-----------
  1     FF   Gi1/2/1  Passive    8
  0     FF   Gi2/2/1  Passive    8

Time since last port bundled:    0d:00h:00m:05s    Gi1/2/1
Time since last port Un-bundled: 0d:00h:00m:33s    Gi1/2/1

Server configuration
       The default configuration on HP servers for a teaming interface is Type: Automatic and Transmit: Automatic. This configuration will attempt to negotiate an etherchannel using LACP and if this fails to use Transmit Load Balancing (TLB). As long as the port-channel and its corresponding physical interfaces are configured correctly the default configuration seems to work well. Although TLB is not our preferred failback connection type, there does not appear to be a way to enable channelling with NFT fallback.

Default Teaming Configuration
Successful LACP negotiation
Unsuccessful LACP negotiation
Other features such as duplex/speed and flowcontrol are best left at defaults.

Jumbo Frames
       Jumbo frames may improve performance of some applications, but no testing has been done at the time of writing to verify whether they introduce problems either locally or to remote users on a 1500 byte MTU WAN connection or whether they do indeed improve performance as much as some would believe. http://www.nanog.org/mtg-0802/scholl.html may be useful reading.
       Jumbo frames are also incompatible with HP’s TCP Offload Engine (TOE) NICs so jumbo frames may suffer from reduced throughput. More testing and investigation will be required before coming to any firm conclusions or recommendations. Therefore at the current time, our recommendation for host access ports is to use a standard 1500 byte MTU / 1518 byte frame size.
       However, since every trunk link on a LAN has to support the highest MTU, it is worth building the LAN’s trunk links to support a high MTU even if the access ports still run at 1514 bytes. This leaves the option open for later adoption at the host layer and allows easy adoption of some devices that require a high MTU such as Fibrechannel over IP. 

No comments: